Every fire safety service a London building needs
Every service from one accredited London team, and the British Standard or regulation each one is worked to, named against it. Start with the fire risk assessment if you are not sure: it is the document that decides the rest.
Assessment & compliance4
Fire alarm systems9
- Fire alarm design Drawings, zones & cause and effect BS 5839-1 · BAFE SP203-1
- Fire alarm installation Installed & certified to BS 5839-1 BS 5839-1 · BAFE SP203-1
- Addressable systems Pinpoint the exact device BS 5839-1 · BAFE SP203-1
- Conventional systems Cost-effective for smaller sites BS 5839-1 · BAFE SP203-1
- Maintenance & servicing Six-monthly, certificate each visit BS 5839-1 · BAFE SP203-1
- Repair & fault finding Panel in fault or repeat false alarms BS 5839-1 · BAFE SP203-1
- System takeover Switch provider, free audit BS 5839-1 · BAFE SP203-1
- Fike alarm service Approved Fike installer BS 5839-1 · BAFE SP203-1
- C-TEC alarm service C-TEC certified engineers BS 5839-1 · BAFE SP203-1
Equipment & passive protection3
Buildings we work in5
- Offices Multi-let buildings and split duty BS 5839-1 · Fire Safety Order 2005
- Shops and retail Trading hours and the public BS 5839-1 · BS 5306-8
- Restaurants and takeaways Kitchens, cellars, late trading BS 5839-1 · BS 5306-8
- Warehouses and industrial Beam, aspirating and in-rack BS 5839-1 · BS EN 12845
- Care homes Evacuation strategy decides the system BS 5839-1:2025
BAFE Registered Organisation 303184 covers scheme SP203-1, fire detection and alarm systems, and appears above only against the alarm services. Every other service names the standard it is carried out to instead. How to verify all of this →
What happens when you get in touch
The same four steps whichever of the sixteen you need, with the price agreed in writing before anyone starts.
-
01
Tell us about the building
One call, or 60 seconds on the form. You speak to an engineer rather than a call centre.
-
02
Free survey and written quote
We walk the premises, explain what the law asks of you, and put the price in writing. No obligation.
-
03
Work done and certified
Carried out to the relevant British Standard, commissioned properly, and certificated on completion.
-
04
Serviced, year after year
Six-monthly visits with a written report every time, so compliance never quietly lapses.
What booking one accredited team actually changes
The difference between sixteen services under one registration and sixteen separate suppliers shows up in the paperwork long before it shows up in the price.
- Renewal dates One schedule covering the assessment, the alarm, the emergency lighting and the extinguishers. One diary Four contractors, four renewal dates, and nobody owning the gaps between them.
- Acting on the assessment The engineers who read the fire risk assessment are the ones who carry out what it specifies. No handoff The assessment sits with one firm and the remedial work with another, so its findings go unactioned for months.
- Paperwork One set of certificates, issued after every visit and filed the same way each time. Insurer ready Certificates arrive in four formats, and the one your insurer asks for is the one nobody can find.
- A fault on a Friday One number, and the engineer already knows the system. 24 to 48 hours You start by working out which supplier covers the panel.
BAFE SP203-1 covers the fire detection and alarm work. The other services are carried out to the standards named at the top of this page.
Good to know before you book
Can one company handle all of our fire safety?
Yes. Flame Shield London designs, installs, services and certifies fire alarm systems, and also carries out fire risk assessments, emergency lighting, extinguisher servicing, fire door checks and staff training. One accredited team, one number to call, one set of paperwork. Our BAFE SP203-1 registration covers the alarm work; every other service is carried out to the British Standard named against it above.
Do you only work on systems you installed?
No. Takeover of existing systems is one of our core services, whoever installed them. The takeover audit is free: we inspect the system, report on its condition and compliance, and quote to take over the servicing with no gap in cover.
Which service should I book if I do not know what the building needs?
Start with the fire risk assessment. It is the duty the Fire Safety Order 2005 places on the Responsible Person, and it is the document that decides the alarm category, the emergency lighting, the extinguishers and the door schedule. Everything else on this page follows from what it finds.
What does the free survey include?
An accredited engineer visits your premises, looks at what the building needs, explains what the law requires, and gives you a clear written quote. It is free, with no obligation, and we explain the price before any work starts.
Where this comes from
- BS 5839-1, fire detection and alarm systems in non-domestic premisesBSI
- BS 5839-6, fire detection and alarm systems in domestic premisesBSI
- BS 5266-1, emergency lighting code of practiceBSI
- BS 5306-3, commissioning and maintenance of portable fire extinguishersBSI
- Regulatory Reform (Fire Safety) Order 2005legislation.gov.uk
We name the standard rather than quoting it. British Standards are copyright of BSI and have to be bought from them; the links above are to the publisher so you can check any figure on this page against the source.
Free survey · No obligation
Not sure which service you need?
Tell us about the building and we will advise. The consultation and the survey are free, and there is no obligation either way.
- BAFE SP203-1 registered for fire alarms, Fike and C-TEC certified
- Written quote before any work starts
- Called back within 24 to 48 hours



