Fire safety for London care homes and supported living

Here the evacuation strategy decides the system, not the other way round. If people are moved sideways rather than out, the compartment has to hold and the staff have to be there.

Free survey and a written quote, with a reply within 24 to 48 hours.

  • BS 5839-1 · residential care premises
  • BAFE SP203-1 (fire alarms)
  • Fike registered
  • C-TEC certified

Book a free care home survey

Step 1 of 3

Four questions. Free survey, free written quote, no obligation.

What do you need help with?

Please choose a service to continue.

Something went wrong sending your request. Please try again, or call 020 3393 1661.

What each accreditation covers, and how to verify it

What this sector needs that others do not

Every other building type on this site can be evacuated by telling people to leave. That is the assumption this sector cannot make.

  1. We start from the strategy

    Simultaneous, progressive horizontal or staff alarm. That answer changes the category, the sounder arrangement and what the panel has to be able to do.

  2. The 2025 change in sleeping rooms, explained

    Smoke, multi-sensor or CO detection is now preferred over heat unless the assessment justifies heat. We tell you whether it affects you rather than using it to sell a replacement.

  3. Doors treated as part of the system

    If the strategy assumes a compartment holds, the door is load-bearing. Hold-opens linked to the alarm let a corridor stay open for care and close on activation.

  4. Nothing sold on a false deadline

    None of the 2025 changes are retrospective. An existing certificated system does not become non-compliant because an edition moved, and we will say so.

The change in the 2025 edition that most operators have not been told about

For years, heat detection was widely specified in bedrooms, mostly to keep unwanted alarms down in rooms where somebody might smoke, use an emollient cream, or set off a smoke detector with a kettle.

BS 5839-1:2025 changed the expectation. Smoke, multi-sensor or carbon monoxide detection is now preferred in sleeping rooms, and heat detection needs to be justified by the fire risk assessment rather than assumed. The reasoning is straightforward: a heat detector responds only once a fire is producing real heat, and in a room where somebody is asleep and may not be able to get themselves out, that is late.

Two things follow, and the second matters as much as the first. It is worth reviewing, because it may genuinely change what your bedrooms should have. And it is not retrospective: an existing certificated system does not become non-compliant because an edition changed. Anyone telling you otherwise is selling something.

What BS 5839-1:2025 actually changed

Sleeping rooms
Smoke, multi-sensor or CO preferred since the 2025 edition. Heat now needs justifying in the assessment.
Stairways
The 2025 edition expects detection in main access and egress stairways for L1, L3 and L4.
Servicing interval
Six-monthly, now with a plus or minus one month tolerance. Five to seven months is inside the standard.
Retrospection
None of it is retrospective. A certificated system stays certificated.
If somebody has told you your building is now non-compliant because BS 5839-1 changed in 2025, ask them to show you where the standard says so. It does not. The changes apply to new design, and to what a fire risk assessment should be looking at on review.

How a care home survey runs

The first question is not about the system. It is about what happens to the people.

  1. 01

    What is the strategy

    Everyone out, moved sideways, or staff first. Nothing else can be specified sensibly until that is written down.

  2. 02

    Staffing at the quietest hour

    A strategy that needs six people and a building that runs on three at four in the morning do not describe the same premises.

  3. 03

    The compartment line, walked

    Doors, closers, and the penetrations above the ceiling. If the strategy assumes the compartment holds, this is the survey.

  4. 04

    Then the system

    Category, detector selection in bedrooms, stairway coverage, and what the existing installation can keep.

Book a free survey

What care home managers and providers ask us

Our bedrooms have heat detectors. Were we told wrong?

Not at the time, and this is worth understanding properly because it is being used to sell people systems they may not need. Heat detection in sleeping rooms was widely specified for years, largely to avoid unwanted alarms. BS 5839-1:2025 changed the expectation: smoke, multi-sensor or carbon monoxide detection is now preferred in sleeping rooms unless the fire risk assessment justifies heat. That is a meaningful change, because a heat detector only responds once a fire is already producing significant heat, which in a room where somebody is asleep is late. It is not retrospective, so an existing certificated system does not become non-compliant, but it is exactly the kind of thing a review of your assessment should now be looking at.

What is progressive horizontal evacuation and does it apply to us?

It means moving residents sideways into an adjoining fire compartment rather than out of the building, which buys time for people who cannot use stairs quickly or at all. Whether it applies is a question for your fire strategy and your fire risk assessment rather than for us, but the thing worth knowing is what it depends on. It only works if the compartmentation actually holds, which means the fire doors, the walls above the ceiling and every service penetration through them. It also only works if there are enough staff on the floor at the time to move people. A strategy that assumes six staff and a building that runs on three at four in the morning is not a strategy.

Can the alarm go to staff first rather than sounding everywhere?

A staff alarm arrangement, where an activation alerts staff before any general evacuation signal, is a recognised option in this sector and is used where a full evacuation signal would cause more harm than good. It is not a default and it is not something to specify from a catalogue: it has to be justified in the fire risk assessment, it depends on staff being present and trained to respond within a defined time, and it changes what the system has to be able to do. We will build it where the assessment calls for it and we will say so if the assessment does not.

Do the fire doors really matter that much?

In this sector they matter more than almost anything else on the system, because the evacuation strategy is usually built on the assumption that a compartment will hold for a defined period. A wedged door, a failed self-closer, a gap where a cable was pulled through a wall, and that assumption stops being true while everybody still believes it. This is also why hold-open devices linked to the alarm are worth the money here: they let a corridor stay open for care, and close on activation, without anybody having to remember.

How often does the system have to be serviced?

Two service visits a year under BS 5839-1 by a competent person, plus the weekly test the responsible person carries out and records. The 2025 edition added a tolerance of plus or minus one month on the six-monthly interval, so five to seven months between visits is inside the standard rather than a lapse, which is useful when a visit falls awkwardly. Emergency lighting needs its monthly function test and annual full-duration test under BS 5266-1, and since the 2025 edition a photometric verification at least every five years.

Where this comes from

We name the standard rather than quoting it. British Standards are copyright of BSI and have to be bought from them; the links above are to the publisher so you can check any figure on this page against the source.

Free survey · No obligation

Start with the strategy, not the system

Tell us how your building evacuates and how many staff are on at night. That pair of answers shapes everything else, and the survey and written quote are both free.

  • BAFE SP203-1 registered for fire alarms, Fike and C-TEC certified
  • Written quote before any work starts
  • Called back within 24 to 48 hours
/* The draft names the page the visitor came from. It used to say "fire alarm work" on all 48, so someone reading about fire risk assessments sent us a message about alarms and we lost the one piece of context the page had already established. reachTopic is the same field the phone strip reads. */