Fire safety for London offices
Single-occupancy or one floor of eight, the work is the same and the paperwork is not. We survey the space, tell you which part of the duty is actually yours, and price only that.
Free survey and a written quote, with a reply within 24 to 48 hours.
- BS 5839-1 · multi-let buildings and split responsibility
- BAFE SP203-1 (fire alarms)
- Fike registered
- C-TEC certified
Book a free office survey
Step 1 of 3Four questions. Free survey, free written quote, no obligation.
Request received
Thanks, we'll call you within 24 to 48 hours to arrange your free survey.
- Service
- We'll call
What happens next
- An engineer calls you to arrange a time, within 24 to 48 hours.
- We survey the building free of charge and put the price in writing.
- You decide once you have the quote. No obligation either way.
Need us sooner? Call 020 3393 1661Mon to Fri 9am–7pm · Sat 10am–3pm
What an office actually needs from us
Offices are the most over-specified building type we quote on, because there is no sleeping risk and the category is easy to inflate.
-
We tell you where your duty stops
In a multi-let building the landlord holds the common parts and you hold your demise. We put the boundary in writing before we quote, so you are not paying twice for the same corridor.
-
The category the assessment asked for
Not the one that sells the most detectors. Most offices land at L3, and we say so when L1 is not justified.
-
False alarms treated as a design fault
A kitchenette that trips the panel every fortnight is a detector in the wrong place, not a reason to isolate a zone. We fix the cause and leave the coverage intact.
-
The whole annual cycle, one diary
Two alarm services, the emergency lighting tests including the new five-yearly photometric check, and the extinguisher service, scheduled together rather than by four different suppliers.
The clause nobody reads before signing a lease
Article 22 of the Fire Safety Order 2005 says that where two or more responsible persons share premises, each must co-operate with the others, co-ordinate their fire safety measures, and take reasonable steps to inform the others of the risks they have created.
In a serviced building or a floor-by-floor let, that is not a formality. It is the clause that decides who tests the alarm, whose assessment covers the stair, who is allowed to change a door, and who the fire officer speaks to when something is wrong. Most tenants have never seen the building’s assessment and most landlords have never seen the tenant’s.
The first thing we do on a multi-let survey is establish which system serves what. Frequently the building panel covers the common parts and the escape routes while the tenant floors are on the same loop, which means a tenant cannot alter their layout without the landlord’s system being involved. Knowing that before you plan a fit-out saves the fit-out.
What we ask a landlord for
- The building assessment
- The landlord’s fire risk assessment for the common parts, in full rather than a summary.
- The evacuation strategy
- Simultaneous or phased, in writing. A tenant cannot write their own plan around a strategy nobody has stated.
- Category and zone plan
- What the building system covers, and which zone your floor sits in.
- The service record
- Who holds the contract and when the last BS 5839-1 visit actually happened.
- Which responsible person holds which part of the building, written down
- Alarm category matched to the assessment, not to the quote
- Detector type chosen per position, so kitchenettes and printers stop tripping the panel
- Manual call points within 45 m travel distance under BS 5839-1:2025
- Escape routes lit to BS 5266-1, including any external route the exit discharges into
- Extinguishers sited to BS 5306-8 and serviced to BS 5306-3
- Zone plan on the wall by the panel, legible and current
- A named person who does the weekly test and a log that shows it happening
Why offices get over-specified
Almost every second opinion we give on an office quote comes down to the same three lines.
- Coverage L3 in most offices: escape routes plus the rooms opening onto them, which is where a fire that traps people starts. Usually L3 L1 everywhere, priced per device, on a building with no sleeping risk to justify it.
- The kitchenette A heat detector or multi-sensor in that position, sited away from the kettle. Coverage kept, false alarms gone. Design fix The zone isolated after an evening call-out, and never restored.
- Multi-let boundaries The demise and the common parts separated in writing before a price is given. Article 22 A quote for the whole floor including a corridor the landlord already services.
- Emergency lighting Monthly function, annual full duration, and the photometric verification BS 5266-1:2025 added. Since Oct 2025 An annual test, and nobody has mentioned the five-yearly measured check.
BAFE SP203-1 covers the fire detection and alarm work. Emergency lighting is carried out to BS 5266-1 and extinguishers to BS 5306.
How an office survey runs
Most of the value is in the first two steps, and both happen before anybody quotes.
-
01
Tell us the tenure
Whole building, one floor, or serviced. That single answer changes which duty is yours and therefore what we are pricing.
-
02
We walk it with the panel log
The log tells the truth about false alarms and isolations in a way that a walk-round on its own does not. We read it before we look at a detector.
-
03
A written position on scope
What is yours, what is the landlord’s, what the assessment requires, and where the two do not currently meet.
-
04
One annual cycle
Alarm, lighting and extinguishers on one schedule, with a certificate after each visit.
What office managers and tenants ask us
We rent one floor. Is fire safety the landlord’s problem or ours?
Both, and the split is the thing that catches people out. In a multi-let building the landlord or managing agent is normally the responsible person for the common parts, the stairs, the main alarm panel and the building’s escape routes. You are the responsible person for the area you occupy, which means your fire risk assessment, your staff training, your extinguishers and your own arrangements for getting people out. Article 22 of the Fire Safety Order goes further and requires responsible persons sharing a building to co-operate, co-ordinate and tell each other about risks. In practice that means asking for the building’s assessment and evacuation strategy in writing, and making sure yours does not contradict it.
Do we need detectors throughout, or just in the corridors?
The fire risk assessment decides, and the vocabulary matters because two of the categories are routinely misread. L4 covers the escape routes only. L3 adds the rooms that open onto those escape routes, which is what most offices end up with, because a fire starting in a room next to the corridor is the one that traps people. L2 is L3 plus specific high-risk areas named in the assessment, such as a server room or a plant room, rather than a coverage level between L1 and L3. Full coverage of every room is L1 and is rarely justified in an office with no sleeping risk.
The kitchenette sets the alarm off every few weeks. What is the fix?
Almost never the fix people reach for, which is disabling the zone. An optical smoke detector reads toast and steam as smoke because in optical terms they are very similar. The correct answer is detector selection: a heat detector or a multi-sensor in that specific position, sited away from the toaster and the kettle, sometimes with a short verification delay on the panel. That keeps the coverage the assessment asked for and stops the false alarms. A zone left isolated after an evening call-out is the failure we find most often, and it is the one that shows up on the panel log.
Our building is eight floors. Does everyone leave at once?
Not necessarily. Taller buildings often use phased evacuation, where the floor of origin and the floor above leave first and the rest follow in sequence, so the stairs do not have to carry the whole building at the same moment. That strategy relies on the compartmentation actually holding, on the alarm being able to sound different messages on different floors, and usually on a voice alarm system rather than sounders. It is a decision that belongs to the building’s fire strategy and the assessment, not to a tenant, and it is one of the things to ask the landlord for in writing.
What does an office actually owe every year?
Two fire alarm service visits under BS 5839-1, with a certificate each time, plus the weekly test you carry out yourself and record. Emergency lighting needs a monthly function test and an annual full-duration test under BS 5266-1, and since the 2025 edition also a photometric verification at least every five years, which is a measured check that light levels still match the design. Extinguishers need a monthly visual check by you and an annual basic service. The fire risk assessment itself has to be reviewed whenever anything material changes and kept under regular review regardless.
Where this comes from
- BS 5839-1, fire detection and alarm systems in non-domestic premisesBSI
- BS 5266-1, emergency lighting code of practiceBSI
- BS 5306-3, commissioning and maintenance of portable fire extinguishersBSI
- Regulatory Reform (Fire Safety) Order 2005legislation.gov.uk
- BAFE, the third-party certification body for scheme SP203-1bafe.org.uk
We name the standard rather than quoting it. British Standards are copyright of BSI and have to be bought from them; the links above are to the publisher so you can check any figure on this page against the source.
Free survey · No obligation
Not sure how much of the building is yours?
That is the question the survey answers first, and it is free. Tell us the tenure and we will tell you where your duty starts and stops before anyone quotes a price.
- BAFE SP203-1 registered for fire alarms, Fike and C-TEC certified
- Written quote before any work starts
- Called back within 24 to 48 hours



